Analog DCD1 servo drive (MAX output: 260 Vac / 50 A) with IGBT bridge. The ideal solution for driving direct current motors.
The DCD1 servo drive is ideal for driving permanent magnet or separately excited wound-field DC servomotors equipped with a speed transducer, with voltages up to 260 V and maximum currents up to 50 A.
The DCD1 features internal analogue circuits with an IGBT bridge and 4-quadrant operation with no deadband at zero speed: the motor shaft is rigidly held even at standstill.
Settings are adjusted using DIP switches, trimmers and test points; diagnostics are indicated by green and red LEDs.
Features
Versions
The DCD1 servo drive offers maximum flexibility for integration and rapid retrofitting of your industrial systems. The available versions span maximum output currents from 6 A to 50 A, with a maximum output voltage of 260 V. To ensure a seamless, plug-and-play retrofit of your equipment, you can request the specific version when ordering, specifying the pairing with your motor's transducer (5 V TTL line driver encoder or DC tacho-generator).
The DCD1 can also be configured as a DC power supply: contact us to find out more.
Further information
Maximum output current: 6 A to 50 A
Maximum output voltage: 1.2 × three-phase supply voltage (MAX 260 V)
Single-phase control supply: 220 V ±10% – 50 mA max., protected by external 250 V – 500 mA fuses
Three-phase power supply: 50 V to 240 V, protected by external fuses as per the user manual
Single-phase power supply: please contact the Alter Elettronica technical department
DC (Direct Current) motors with speed sensors:
- permanent magnet
- wound-field with separate excitation, supplied with a constant and independent power supply.
The speed transducers supported by the DCD1 converter are:
- DC (Direct Current) Tachogenerator
- 5V TTL Encoder with Line Driver + Hall Effect Sensors
NOTE: Please specify the type of transducer when ordering.
- Differential input for speed reference
- Adjustable and disableable ramp on the speed signal
- Analogue input for external setting of the current limit
- Analogue output proportional to motor speed
- Analogue output proportional to motor current
- Opto-isolated logic controls: 15–30 V DC, 10 mA max
- LEDs indicating operating status and alarms
- Digital input to perform a "Reset of stored alarms" from the drive
- "Drive Operational" signal via a NO relay contact
- Three-phase line inductor
- Three-phase line filter
- External fuse holder
- Ultra-fast fuses
- External braking resistor
- Capacitive module for DC-BUS